Series 1: DJ jet-Pulse uni-filters series
1. General Description
DJ jet-Pulse uni-filters series is a kind of minitype bag filter which
adopts the Jet Filter Bag cleaning Technology of High Flow rate Pulse
Valve with 0.5~0.7Mpa. It has the characteristics such as strong bag
cleaning capacity and high collection efficiency. And it is small and
light, the structure is simple and compact, which is easy to install
and maintain. It is widely used in the various conveying facilities
and dedusting for partial dust emission points in the industries such
as building materials, metallurgy, mine and coal and so on.
2. Operational
Principle
The dusty gas enters the filter bag chamber, after filtrated by filter
bag to get net gas, which enters the net gas chamber and then discharged
by the fan from the outlet of the net gas chamber. Along with the adsorption
of the dust on the external surface of the filter bag, the resistance
of dust catcher rises gradually. In order to make the resistance of
dust catcher less than 1200Pa, it is necessary to carry on time bag
cleaning. Bag cleaning is accomplished by program controller regularly
to start the pulse valves in turn; the compressed air in the air pocket
is jetted out by the tuyere. Induce ambient air enter the filter bag
through venturi tube and instantly expand the filter bag sharply, shake
off the dust in the filter bag to clean the bag.
3. Structure &
Selection of Models
This series of dust catcher consists mainly of the following parts:
Box: Including the middle box, upper box, porous plate, filter bag,
filter bag frame, access door. The box can withstanding pressure of
5000Pa and has three structures: one with ash bucket, another is open
flange; the last one is belt conveyor filter.
Jet System: air pocket, tuyere, pulse valve, pulse controller.
Blast System: fan, electric machinery.
1) Model Directions
These uni-filters have seven specifications 32, 48,64,80,96,112,128,
of which there are three mounted forms for each specification to meet
operating requirements in different occasions
and the model directions are detailed as follows:
2) Selection Parameters & Selection Principle:
a. The main technological parameters for dust catcher selection are
gas flow rate, gas temperature, dust concentration and humidity. The
maximum values of gas flow rate, gas temperature and dust concentration
designed according to the techniques shall be slightly smaller than
the numerical values in the technical performance chart. And the corresponding
model of dust catcher, viz. the needed dust catcher model.
b. The air consumption in the chart is the circumstances of the centralized
air supply by the plant. If the air compressor is used exclusively,
the air consumption in the chart shall be magnified to 1.5 times.
c. The air consumption set forth in the blank of consumption for compressed
air is the maximum air consumption of this model.
3) As to the shape
and base of the equipment, see the attached drawings. And our corporation
can also design the shape of dust catcher according to the state of
user's ground and user's requirements.
|
|